1. Drying Time Table
PNEG-1915 VN2 Portable Dryer Drying Charts for All Models of Vision
11
Drying Time Table……..1114 and D320 (Continued)
Corn...Full Heat (Continuous Flow)
Wheat, Barley, Milo...Dry and Cool (Automatic Batch)
The above drying capacities are estimates based on drying principles, field results and computer
simulations. Variances may occur due to grain physiological factors (kernel size, chemical composition,
variety, maturity), excessive fines, weather conditions, etc.
190°F
210°F
230°F
Moisture
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% In
% Out*
18
17
91
10
1802
19
17
55
17
1074
62
15
1228
20
17
41
23
798
46
20
912
52
18
1026
21
17
33
28
649
38
24
742
42
22
835
22
17
28
33
553
32
28
632
36
25
711
23
17
24
37
482
28
33
551
31
29
620
24
17
22
42
426
25
37
487
28
33
548
25
17
19
48
379
22
42
433
25
37
487
26
17
17
53
338
20
47
386
22
41
435
27
17
15
60
302
18
52
345
20
46
388
28
17
14
67
270
16
58
309
18
52
347
29
17
12
74
242
14
65
277
16
58
311
30
17
11
83
218
13
72
249
14
64
280
31
17
10
92
196
11
80
224
13
71
252
32
17
9
101
178
10
89
203
12
79
228
33
17
8
111
161
9
98
185
11
87
208
34
17
7
122
148
9
107
169
10
95
190
35
17
7
132
136
8
116
155
9
103
175
*Represents the target moisture out of the dryer. Expected final moisture in the bin is…...15.0%
Drying table based on 100% meter roll speed of…...1970 BPH
140°F
155°F
175°F
Moisture
Dry
(Min.)
Cool
(Min.)
Capacity
Dry (BPH)
Dry
(Min.)
Cool
(Min.)
Capacity
Dry (BPH)
Dry
(Min.)
Cool
(Min.)
Capacity
Dry (BPH)
% In
% Out
15
13
32
15
316
28
15
344
16
13
43
15
267
37
15
293
31
15
325
17
13
53
15
233
45
15
258
38
15
288
18
13
62
15
208
53
15
232
45
15
260
19
13
71
15
188
61
15
210
51
15
237
20
13
81
15
171
69
15
192
58
15
217
21
13
91
15
156
78
15
175
66
15
200
22
13
102
15
142
88
15
161
74
15
183
23
13
114
15
130
98
15
147
82
15
169
Drying table based on 100% meter roll speed of…...1970 BPH
Unload timer set for…...9.1 minutes