Drying time table…… 6 and d370 (continued), Drying time table – Grain Systems PNEG-1915 User Manual
Page 14

1. Drying Time Table
14
PNEG-1915 VN2 Portable Dryer Drying Charts for All Models of Vision
Drying Time Table……..1116 and D370 (Continued)
Corn...Full Heat (Continuous Flow)
Wheat, Barley, Milo...Dry and Cool (Automatic Batch)
The above drying capacities are estimates based on drying principles, field results and computer
simulations. Variances may occur due to grain physiological factors (kernel size, chemical composition,
variety, maturity), excessive fines, weather conditions, etc.
190°F
210°F
230°F
Moisture
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% Unload
Rate
Dry Time
(Min.)
Capacity
Dry (BPH)
% In
% Out*
18
17
87
10
1963
19
17
52
18
1170
59
15
1337
20
17
39
24
869
44
21
993
50
18
1118
21
17
31
29
707
36
25
808
40
23
909
22
17
27
34
602
31
30
688
34
27
774
23
17
23
39
525
27
34
600
30
30
675
24
17
21
44
464
24
39
530
27
34
597
25
17
18
50
413
21
44
472
24
39
531
26
17
16
56
368
19
49
421
21
43
473
27
17
15
63
329
17
55
376
19
49
423
28
17
13
70
294
15
61
336
17
54
379
29
17
12
78
264
13
68
302
15
61
339
30
17
11
87
237
12
76
271
14
68
305
31
17
9
96
214
11
84
244
12
75
275
32
17
9
106
193
10
93
221
11
83
249
33
17
8
117
176
9
102
201
10
91
226
34
17
7
128
161
8
112
184
9
99
207
35
17
7
139
148
8
122
169
8
108
191
*Represents the target moisture out of the dryer. Expected final moisture in the bin is…...15.0%
Drying table based on 100% meter roll speed of…...2251 BPH
140°F
155°F
175°F
Moisture
Dry
(Min.)
Cool
(Min.)
Capacity
Dry (BPH)
Dry
(Min.)
Cool
(Min.)
Capacity
Dry (BPH)
Dry
(Min.)
Cool
(Min.)
Capacity
Dry (BPH)
% In
% Out
15
13
32
15
362
28
15
394
16
13
43
15
305
37
15
335
31
15
371
17
13
53
15
267
45
15
295
38
15
329
18
13
62
15
238
53
15
265
45
15
297
19
13
71
15
215
61
15
240
51
15
271
20
13
81
15
195
69
15
219
58
15
249
21
13
91
15
178
78
15
200
66
15
228
22
13
102
15
162
88
15
184
74
15
210
23
13
114
15
148
98
15
168
82
15
193
Drying table based on 100% meter roll speed of…...2251 BPH
Unload timer set for…...9.1 minutes