RETROFITTING A DIGITAL TEMPERATURE INDICATION

21.1

DATA FOR MOUNTING

Display

LCD 10mm, unit °C

Display range

-30°C to +30°C

Measuring period

2,5 per second

Ambient temperature range

0°C to +50°C

Main supply

4,5V to 15V, 2mA

Housing

ABS plastics black

Protection

IP50 for the front
IP00 for the back

(DIN 40050)

Locating distance

30,5mm x 57mm (H x W)

Fitting length

73mm

Data according to the technical description DPM 528, Schwille Elektronik.


21.2

INSTALLATION INSTRUCTIONS

N O T E !

The safety instructions specific to the plant and process are to be consulted
prior to installation, maintenance and inspection.

The cooler EC/ECS must be disconnected from all power supplies prior to
installation, maintenance and inspecttion!


The digital temperature display is mounted in the front panel of the EC/ECS cooler. Figure 12 shows
the positioning and the necessary locating distance.

°C>

ON

°C<

310

40

40

30,5

57

Figure 14 Locating distance of digital temperature indication