The Lipsync parameter is the del
positive value means video is a
ay (in ms) between video and audio signals. A
head of audio. A negative value means audio
ahead of video.
This parameter is also available from the Channel Parameters option of the EVS
Maintenance menu. Changing the Lipsync value in the Setup menu will update it
in the EVS menu and vice versa.
This adjustment is done during the record
will apply for the next recorded pictures only.
Note
process. A new Lipsync value
3.11.3
is parameter enables/disables the display of audio meters at the bottom of each
output monitor.
3.11.4
This parameter allows adjusting the sensitivity of audio meters on the OSD of the
tput monit
o itive value means that the meters will be more sensitive.
3.11.5
This parameter defines to which audio outputs the Aux. Track of the playlist will
Prv (default)
The Aux. Track will use the audio outputs normally assigned to
channel. If no PRV channel is available, the Aux
not be assigned to any audio output.
A
UDIO METERS ON
OSD
Possible values: Yes (default) / No
Th
A
UDIO METERS ADJ
.(
DB
)
Possible range: -83.2 to 0 dB. Default: 0.0 dB
ou
ors. A p s
A
UX TRACK OUTPUT
Possible values: Prv / Prv&7-8/15-16 / PGM
be played out of.
Value Meaning
the PRV
Track will
Prv&7-8/15-16
The Aux. Track will use the audio outputs normally assigned to
the PRV channel if there is one, plus all the audio outputs
from 7-8/15-16 that have not yet been assigned to another
channel. Use this option if you need an aux track without PRV
channel available.
PGM
The Aux. Track will use the audio outputs normally assigned to
the PGM channel.