B: M
ANAGEMENT
S
OFTWARE
U
PGRADE
U
TILITY
c Copy the management software file to the
upgrade
directory on the
hard drive.
d Change your directory to the
upgrade
directory on the hard drive.
5 At the MS-DOS prompt, enter the upgrade command:
update
is the name of the management software file. Note that the
software files have the format
s2sxx_yy.bin
, where
xx_yy
is the
version number.
CAUTION: You must use the
s2sxx_yy.bin
format, otherwise the
upgrade fails.
You can also use the following parameter with the upgrade command to
specify the serial (COM) port to use for the PC (COM 1) or (COM 2). The
default for this is COM 1:
-c 1
or
-c 2
An example of the upgrade command with this parameter is:
update -c 1 s2sxx_yy.bin
6 Power-down the Switch.
7 At your PC, press [Return].
8 Power-up the Switch immediately (within 5 seconds).
The utility transfers the management software to the Switch.
When the management software has been transferred, your PC displays
the following message:
Update completed successfully.
Update another unit? (y/n)
9 If you want to upgrade the management software of another Switch,
enter
y
(for yes), otherwise, enter
n
(for no).