ZyXEL Communications Omni 56K II User Manual
Page 80
Omni 56K II and Omni 56K Plus II User’s Guide
5-34
Command
Sets
COMMAND BIT DEC HEX
FUNCTION
AND
DESCRIPTION
REF.
0
to
255
0-FF
To process the CND, silence must be detected for the
specified interval, in 20 ms units.
bit dec hex Bit-mapped
register.
+000
0
1
1
This causes CND information to be reported in raw
format.
2
4
4
This enables the sending of data calling tones (CNG).
3 8 8 Reverses
the
V.23
channel speed. Originate mode
modem speed (Send/Receive) 1200/75; Answer mode
modem speed (Send/Receive) 75/1200.
&N12
S48=
4
16
10
(Works with the &D1 command) DTR ON causes the
modem to dial the default number and DTR OFF
causes the modem to hang-up and reset to profile 0.
When the modem is idle (waiting for a command), it
does not dial any number when DTR changes from
ON to OFF.
bit Dec
hex Bit-mapped
register.
+000
7
0
0
Select 'Mark' as the first signal of the V.23
handshaking sequence (default).
&N12
S52=
128
80
Select 'Space' as the first signal of the V.23
handshaking sequence (default).
&N12
bit dec hex
+000
S56=
0
to
255
0-FF
Hook flash detect time, in units of 10ms. A value of
zero uses country-specific default duration.
bit dec hex Bit-mapped
register.
+016
S57=
4
16
10
Enables the reporting of Class 1 capability in response
to +FCLASS=?
Bit
S-register bit number, 'b', used in 'ATSr.b=n' and 'ATSr.b=?'
Dec
Decimal value, 'x', used in 'ATSn=x'
Hex
Equivalent Hexadecimal value.
+nnn
Factory default when listed in 'Reference' column.
Note:
AT' is omitted when an AT command is referred to in the 'Reference' column.