Voice at commands, 3 voice at commands – ZyXEL Communications Omni 56K II User Manual
Page 68

Omni 56K II and Omni 56K Plus II User’s Guide
5-22
Command
Sets
5.3 Voice
AT
Commands
Table 5-12 Voice AT Commands
COMMAND FUNCTION OPTION
DEFAULT
DESCRIPTION
+FLO
Select Flow control.
0,1,2
2
0: NO flow control.
1: (XON/XOFF)Software flow control.
2: (RTS/CTS)Hardware flow control.
+VIP Initialize
parameters.
N/A N/A
+VSD=15,70 (15*4, 7 second)
+VTD=100 (1 second)
+VRN=10 (10 second)
+VRA=70 (7 second)
+VGR=0 (Enable AGC)
+VGT=128
+FLO=2 (RTS/CTS)
+VIT=70 (7 second)
+FCLASS Voice/data/fax
selection
0,1,2.0,8 0
0:
DATA.
1: CLASS 1 FAX.
2.0: CLASS 2.0 FAX.
8: VOICE.
+FMI? Manufacturer
ID.
N/A ZyXEL
+FMM?
Model ID
N/A
Omni 56K
II or Omni
56K Plus II
+FMR? Revision
N/A V1.x
+VRX
Voice recording
N/A
N/A
Start recording.
+VGR
Set the gain for the
received voice
sample.
0
0
0: Automatic gain control (AGC)
+VGT
Set the gain for the
transmitted voice
sample.
0-255 128 0:
Silence
1-255: The larger the value, the louder
the voice will be.
+VLS
Select a voice I/O
device.
0,1 (Omni
56K Plus II
only), 2
0
0: The DCE is on hook. A local phone
is connected to the Telco line.
1: The DCE is on-hook and is
connected to the local phone. Power
is also provided to the local phone.
The modem can record/play through