Renesas R61509V User Manual
Page 73
R61509V
Target
Spec
Rev. 0.11 April 25, 2008, page 73 of 181
Power Control3 (R102h)
Note: True values of PSON and PON are not read when instruction read is executed.
PON, PSON: Turn power supply ON. PON and PSON must be written to power supply ON and start the
internal power supply operation. Follow power supply sequencer to set PON and PSON bits.
VCMR: Selects either external resistance (VCOMR pin) or internal electronic volume (VCM[4:0]) to set
the electrical potential of VCOMH. The internal electronic volume is set by VCM bits
Table 44
VCMR0[0]
VCOMH Electrical Potential setting
0 VCOMR
(externally
supplied)
1 Internal
electronic
volume
VRH[3:0]: Sets the factor to generate VREG1OUT.
Table 45
Note: Write VC and VRH bits so that VREG1OUT ≤ DDVDH-
0.5V.
R/W RS IB15 IB14 IB13 IB12 IB11 IB10 IB9
IB8
IB7
IB6
IB5
IB4
IB3 IB2 IB1 IB0
VRH
[4]
VRH
[3]
VRH
[2]
VRH
[1]
VRH
[0]
0 0
VCM
R
1 0
PSON PON
0 0 0 0
R/W 1
R/W R/W R/W R/W R/W
R/W R/W
W
W
Default
0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0
VRH[4:0] VREG1OUT
5’h00 Halt
(Hiz)
5’h01-5’h0F
Setting inhibited
5’h10
VCIR x 1.600
5’h11
VCIR x 1.625
5’h12
VCIR x 1.650
5’h13
VCIR x 1.675
5’h14
VCIR x 1.700
5’h15
VCIR x 1.725
5’h16
VCIR x 1.750
5’h17
VCIR x 1.775
5’h18
VCIR x 1.800
5’h19
VCIR x 1.825
5’h1A
VCIR x 1.850
5’h1B
VCIR x 1.875
5’h1C
VCIR x 1.900
5’h1D
VCIR x 1.925
5’h1E
VCIR x 1.950
5’h1F
VCIR x 1.975