RIC-155 Installation and Operation Manual

Appendix B Traffic Separation

Port-Based/VLAN-Based Traffic Separation

B-5

MNG

Host

Uplink

Data

Secure

Secure

Fallback

Tag Stripping Enabled

Fallback

Stack

Figure B-5. Port Access Mode – None

MNG Only

In the MNG Only port access mode, local data frames can reach the uplink port
only. Local management frames can reach the host and uplink ports, and the
remote management frames can reach the local uplink, host and data ports.
In the MNG Only access mode, the host port checks the source port of the
incoming frames and drops those that do not originate from the management port.
See

Managing RIC-155 via MNG Port

for the application example.

MNG

Host

Uplink

Data

Secure

Secure

Fallback

Tag Stripping Enabled

Fallback

Stack

Figure B-6. Port Access Mode –MNG Only

All

In the All port access mode, data and management frames can reach all ports,
allowing management of the local and remote units via the MNG and DATA ports.
If the units are going to be managed via the DATA port, it is necessary to add
VLAN tags to the frames before they enter RIC-155. This can be done by an
external device, such as a switch. In this case the host must be configured to tag
the incoming management frames according to the setting of the external switch.
See

Managing RIC-155 via Data Port

for the application example.

MNG

Host

Uplink

Data

Secure

Secure

Fallback

Tag Stripping Disabled

Fallback

Tag

Figure B-7. Port Access Mode – All