Figure 5-4, Table 5-1 – RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 User Manual
Page 63
RIC-155 Installation and Operation Manual
Chapter 5 Troubleshooting and Diagnostics
Monitoring Performance
5-3
RIC-155
Uplink Statistics
Time Elapsed ...(6) Far End Line ESs ... (7)
LOS ... (0) Far End Line SES ... (5)
Section CV ... (6) Far End Line UASs ... (6)
Section ESs ... (6) Path CV ... (2)
Section SESs ... (6) Path ESs ... (6)
Section SEFSs ... (4) Path SESs ... (6)
Line CV ... (10) Path UASs ... (0)
Line ESs ... (7) Far End Path CV ... (10)
Line SESs ... (6) Far End Path ESs ... (7)
Line UASs ... (3) Far End Path SESs ... (9)
Far End Line CV ... (0) Far End Path UASs ... (1)
... (N)
>
ESC-prev.menu; !-main menu; &-exit;
Figure 5-4. Uplink Statistics Screen, Page 1
RIC-155
Uplink Statistics
...(P)
Time Elapsed ... (.)
RCV frames ... (6) RCV FCS frames ... (6)
XMT frames ... (10) RCV ABORT frames ... (6)
XMT ABORT frames ... (10)
>
ESC-prev.menu; !-main menu; &-exit;
Figure 5-5. Uplink Statistics Screen, Page 2
Table 5-1. SDH/SONET Statistics Parameters
Display Description
Range
[15 min]
Time Elapsed
Number of seconds that have elapsed since the beginning of the current
interval.
0–899
LOS
Number Loss of Signal errors occurred during the current interval.
0–899
Section CV
Number of Section Coding Violations occurred during the current interval.
Section CVs are not counted during SES_S.
0–899