Chapter 4 Configuration

Configuring RIC-155 for Management

4-5

RIC-155


Manager List
Manager ID IP address Trap Mask
1. 0.0.0.0 NO
2. 0.0.0.0 NO
3. 0.0.0.0 NO
4. 0.0.0.0 NO
5. 0.0.0.0 YES

ESC-prev.menu; !-main menu; &-exit; ?-help

Figure 4-6. Manager List Menu

Controlling the Management Access

You can enable or disable access to the RIC-155 management system via SNMP,
Telnet or Web-based applications. By disabling SNMP, Telnet or Web, you prevent
unauthorized access to the system when security of the RIC-155 IP address has been
compromised. When SNMP, Telnet and Web access is disabled, RIC-155 can be

managed via an ASCII terminal only. In addition, you can enable or disable an
inband management (via uplink or DATA port) or out-of-band (via MNG port).

To define the management access method:
1. Follow the path: Configuration > System Configuration > Management >

Management Access

.

The Management Access menu appears.

2. From the Management Access menu, select TELNET Access to configure

Telnet access, select SNMP Access to configure SNMP access, or select WEB
Access

to configure Web access.

A TELNET Access, SNMP Access or WEB Access menu appears
(see

Figure 4-7

).

During a Telnet session, Telnet Access is masked.
During a SNMP session, SNMP Access is masked.
During a Web session, Web Access is masked.

3. From the TELNET Access, SNMP Access or WEB Access menu, select ENABLE

to allow selected management type, DISABLE to restrict it, or Managers Only
to allow access only for the management stations defined in the Manager List
menu (see

Figure 4-6

).

4. If the Web management (ConfiguRAD) is enabled, you can select WEB Trace

Refresh

from the Management Access menu, and define refresh rate of the

Trace pane in seconds (1255).

Note