Configuring the pos bridge port – RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 User Manual
Page 50
Chapter 4 Configuration
RIC-155 Installation and Operation Manual
4-14
Configuring the Internal Bridge
Tag Stripping
(specifies whether the port strips the VLAN tags at egress or
not)
Enable
(the tags are stripped)
Disable
(the frames are left unchanged).
Whenever the Physical Ports Access mode is changed, Tag Stripping is set to its
default value, as explained in
Appendix B
.
RIC-155
DATA Port
1. PVID [1 – 4094]
<2>
2. PVID priority
<2>
3. Tag Stripping
Please select item <1 to 3>
ESC-prev.menu; !-main menu; &-exit
Figure 4-16. DATA Port Menu
Configuring the POS Bridge Port
The POS bridge port receives frames coming from the Ethernet management and
data ports. The POS port can be configured to add a tag identifying the source
port of the outgoing frames.
To configure the POS port:
1. Follow the path: Configuration > Bridge Configuration > POS Port Egress.
The POS Port Egress menu is displayed.
2. From the POS Port Egress menu, select one of the following POS port values:
Unmodified
(POS port leaves outgoing frames unchanged)
Tag
(POS port adds a tag only if the frame is untagged)
Stack
(POS port adds tags to all frames, tagged or untagged).
Whenever the Physical Ports Access mode is changed, POS Port Egress is set to its
default value, as explained in
Appendix B
.
Note
Note