beautypg.com

RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 User Manual

Page 71

background image

RIC-155 Installation and Operation Manual

Chapter 5 Troubleshooting and Diagnostics

Handling Alarms

5-11

Terminal Message

Description

Severity

Path Remote Defect
Indication

Path Remote Defect Indication signal is detected

Minor

Path Excessive Error

Defect

Number of the Path Excessive Error Defect errors exceeds

threshold

Major

Path Signal Degraded
Error

Number of Path Signal Degraded Errors exceeds threshold

Major

Path Trace J1 string

mismatch

Rx path trace information mismatch is detected

Major

Uplink port signal loss

Receive signal loss is detected on the uplink

Major

Data 1 Ethernet port

down

Data integrity failure is detected at the primary Ethernet port

Major

Management Ethernet
port down

Data integrity failure is detected at the management port

Major

Table 5-3. RIC-155 Events

Number Terminal

Message

Description

23

Downloading...

Software download has started

24

Downloading failure

Software download has failed

25

User password has been

changed

User password has been changed

27

User login has been

changed

User name has been changed

32

Alarm log is full

More than 200 entries registered in the alarm log file