Tagging modes of the bridge ports, Uplink and host ports, Management and data ports – RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 User Manual
Page 77: Default tagging
RIC-155 Installation and Operation Manual
Appendix B Traffic Separation
Port-Based/VLAN-Based Traffic Separation
B-3
Tagging Modes of the Bridge Ports
Each frame is routed according to its VID. If the frame is untagged, it receives tag
at egress from the uplink port.
Uplink and Host Ports
The uplink port operates in the following tagging modes:
• Unmodified – frames (tagged and untagged) are left unchanged.
• Tag – untagged frames are tagged and tagged frames are left unchanged.
• Stack – all frames (tagged and untagged) receive tags.
The host port of the internal bridge can be configured to add VLAN ID tags to the
frames.
Management and Data Ports
The management and data ports can strip the frame tags at egress or leave the
frames unchanged.
Default Tagging
Whenever the port access mode (None, MNG only or All) or forwarding mode of
the bridge (Filter or Filter Tagged) is changed, the tagging modes of the bridge
ports are set to one of the default tagging modes, as illustrated in
. This is
made to simplify the bridge configuration procedure for the most common
applications.
Table B-1. Default Tagging Modes
Forwarding Mode
Filter Tagged
Management Access Mode
Port
Filter
None MNG
Only
All Local
MNG
Only
MNG Tag
stripping
disabled
Tag stripping
enabled
Tag stripping
enabled
Tag stripping
enabled
Tag stripping
enabled
Data Tag
stripping
disabled
Tag stripping
enabled
Tag stripping
enabled
Tag stripping
disabled
Tag stripping
enabled
Host Tag
stripping
enabled
Tag stripping
enabled
Tag stripping
enabled
Tag stripping
enabled
Tag stripping
enabled
Uplink Tag
stripping
disabled
Stack Stack Tag
Stack