RIC-155 Installation and Operation Manual

Appendix B Traffic Separation

Port-Based/VLAN-Based Traffic Separation

B-3

Tagging Modes of the Bridge Ports

Each frame is routed according to its VID. If the frame is untagged, it receives tag
at egress from the uplink port.

Uplink and Host Ports

The uplink port operates in the following tagging modes:
• Unmodified – frames (tagged and untagged) are left unchanged.
• Tag – untagged frames are tagged and tagged frames are left unchanged.
• Stack – all frames (tagged and untagged) receive tags.

The host port of the internal bridge can be configured to add VLAN ID tags to the

frames.

Management and Data Ports

The management and data ports can strip the frame tags at egress or leave the

frames unchanged.

Default Tagging

Whenever the port access mode (None, MNG only or All) or forwarding mode of

the bridge (Filter or Filter Tagged) is changed, the tagging modes of the bridge
ports are set to one of the default tagging modes, as illustrated in

Table B-1

. This is

made to simplify the bridge configuration procedure for the most common
applications.

Table B-1. Default Tagging Modes

Forwarding Mode

Filter Tagged

Management Access Mode

Port

Filter

None MNG

Only

All Local

MNG

Only

MNG Tag

stripping

disabled

Tag stripping
enabled

Tag stripping
enabled

Tag stripping
enabled

Tag stripping
enabled

Data Tag

stripping

disabled

Tag stripping

enabled

Tag stripping

enabled

Tag stripping

disabled

Tag stripping

enabled

Host Tag

stripping

enabled

Tag stripping

enabled

Tag stripping

enabled

Tag stripping

enabled

Tag stripping

enabled

Uplink Tag

stripping

disabled

Stack Stack Tag

Stack