Masking port alarms, Figure 5-13 – RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 User Manual
Page 70
Chapter 5 Troubleshooting and Diagnostics
RIC-155 Installation and Operation Manual
5-10 Handling
Alarms
You can always reset all alarm severity values to their default settings by selecting
Default Alarms Settings from the Alarm Configuration menu.
RIC-155
System alarms
Alarm Name
Default Severity
Severity
Mask
1. Self-test failure
Major
Major OFF
2. Line Excessive Error Defect
Major
Major OFF
| 3. Line Signal Degraded Error
Major
Minor OFF
v 4. Loss Of Signal Major
Minor
OFF
5. Loss Of Frame
Major
Minor
OFF
1. Minor
2. Major
ESC-prev.menu; !-main menu; &-exit; ?-help
Figure 5-13. System Alarms Menu
Masking Port Alarms
RIC-155 management software allows you to mask alarms to prevent them from
being reported.
To mask RIC-155 alarms:
1. From the System Alarms menu, select Mask column of the alarm that you
intend to mask by moving cursor up/down or left/right.
2. Mask alarm by selecting ON or remove alarm masking by selecting OFF.
Table 5-2. RIC-155 Alarms and Warnings
Terminal Message
Description
Severity
Self test failure
Failure occurred during self-test
Major
Line Excessive Error
Defect
Number of the Line Excessive Error Defect errors exceeds
threshold
Major
Line Signal Degraded
Error
Number of the Line Signal Degraded Errors exceeds threshold
Major
Uplink Port Loss Of
Signal
Loss of Lock is detected
Major
Uplink Port Loss Of
Frame
Loss of Frame is detected
Major
Line AIS: remote
Ethernet port
Alarm Indication Signal is received from the Ethernet interface of
the remote device
Minor
Line Remote Defect
Indication
Line Remote Defect Indication signal is detected
Minor
Path AIS: Rx Facility
Defect
Path Alarm Indication Signal is detected
Minor
Path Rx Facility Pointer
loss
Path Loss Of Pointer defect is detected
Minor