Chapter 5 Troubleshooting and Diagnostics

RIC-155 Installation and Operation Manual

5-10 Handling

Alarms

You can always reset all alarm severity values to their default settings by selecting

Default Alarms Settings from the Alarm Configuration menu.

RIC-155

System alarms

Alarm Name

Default Severity

Severity

Mask

1. Self-test failure

Major

Major OFF

2. Line Excessive Error Defect

Major

Major OFF

| 3. Line Signal Degraded Error

Major

Minor OFF

v 4. Loss Of Signal Major

Minor

OFF

5. Loss Of Frame

Major

Minor

OFF

1. Minor
2. Major

ESC-prev.menu; !-main menu; &-exit; ?-help

Figure 5-13. System Alarms Menu

Masking Port Alarms

RIC-155 management software allows you to mask alarms to prevent them from

being reported.

To mask RIC-155 alarms:
1. From the System Alarms menu, select Mask column of the alarm that you

intend to mask by moving cursor up/down or left/right.

2. Mask alarm by selecting ON or remove alarm masking by selecting OFF.

Table 5-2. RIC-155 Alarms and Warnings

Terminal Message

Description

Severity

Self test failure

Failure occurred during self-test

Major

Line Excessive Error
Defect

Number of the Line Excessive Error Defect errors exceeds
threshold

Major

Line Signal Degraded
Error

Number of the Line Signal Degraded Errors exceeds threshold

Major

Uplink Port Loss Of

Signal

Loss of Lock is detected

Major

Uplink Port Loss Of
Frame

Loss of Frame is detected

Major

Line AIS: remote

Ethernet port

Alarm Indication Signal is received from the Ethernet interface of

the remote device

Minor

Line Remote Defect
Indication

Line Remote Defect Indication signal is detected

Minor

Path AIS: Rx Facility
Defect

Path Alarm Indication Signal is detected

Minor

Path Rx Facility Pointer

loss

Path Loss Of Pointer defect is detected

Minor

Note