Changing the control port data rate, Configuring the security timeout, Enabling and disabling pop-up alarms – RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 User Manual
Page 44
Chapter 4 Configuration
RIC-155 Installation and Operation Manual
4-8
Configuring the RIC-155 for Operation
Changing the Control Port Data Rate
To configure the control port data rate:
1. From the Control Port menu, select Baud Rate.
The Baud Rate menu appears (see
2. Select the terminal rate by typing the number corresponding to the desired
value, and pressing
3. From the Control Port menu, select Save All to save the new baud rate.
RIC-155
Baud Rate (9600)
1. 9600 bps
2. 19200 bps
3. 38400 bps
4. 57600 bps
5. 115200 bps
Please select item <1 to 5>
ESC-prev.menu; !-main menu; &-exit
Figure 4-11. Baud Rate Menu
Configuring the Security Timeout
The timeout specifies a time interval after which RIC-155 automatically
disconnects from the supervisory terminal if no input from the user is detected.
The timeout can be set to 10 minutes or disabled.
To configure the security timeout:
• From the Control Port menu, select Security Timeout to disable it (OFF) or set
to 10 minutes (10min).
The display is refreshed and a new value appears.
Security timeout value is not valid for the Telnet or ConfiguRAD management,
which are permanently set to 10 minutes.
Enabling and Disabling Pop-up Alarms
When the pop-up function is enabled, RIC-155 displays alarms as they are
generated by the system or received by the interfaces. The alarms are displayed at
the bottom of the terminal screen.
To enable or disable pop-up alarms:
• From the Control Port menu, select Pop Alarm to choose the pop-up alarms
mode: ON (pop-up alarms are enabled) or OFF (pop-up alarms are disabled).
The display is refreshed and a new value appears.
Note