• Management 10/100BaseT port
• STM-1/OC-3c port.
Configuring the Ethernet Interface
To configure the Ethernet interface:
1. Follow the path: Physical Ports Configuration > Ethernet Configuration >
DATA Port
or MNG Port.
DATA Port or MNG Port menu appears (see
2. From the DATA Port or MNG Port menu, configure the following parameters:
Autonegotiation
(Enable or Disable)
Flow Control
(Enable or Disable)
Ethernet Mode
(Full Duplex or Half Duplex)
LAN Speed
(10 Mbps or 100 Mbps).
RIC-155
DATA Port
1. Auto-negotiation:
(Disable)
2. Flow Control:
(Enable)
3. Ethernet Mode:
(Full Duplex)
4. LAN Speed: (100 Mbps)
Please select item <1 to 4>
ESC-prev.menu; !-main menu; &-exit
Figure 4-12. DATA Port Menu
If autonegotiation is enabled, the Ethernet Mode and LAN speed options are masked.
Configuring the STM-1/OC-3c Interface
The STM-1/OC-3c interface of RIC-155 is based on the SDH/SONET framer that
implements mapping functions of a channel for SDH/SONET processing at
155.52 Mbps.
To configure STM-1/OC-3c interface:
1. Follow the path: Configuration > Physical Ports Configuration > Uplink
Configuration
.
The Uplink Configuration menu appears (see
2. From the Uplink Configuration menu, configure the following parameters
Note