Configuring the ric-155 for operation, Figure 4-7, 2 configuring the ric-155 for operation – RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 User Manual
Page 42
Chapter 4 Configuration
RIC-155 Installation and Operation Manual
4-6
Configuring the RIC-155 for Operation
RIC-155
TELNET Access (Enable)
1. Enable
2. Disable
3. Managers only
Please select item <1 to 3>
ESC-prev.menu; !-main menu; &-exit
Figure 4-7. TELNET Access Menu
To enable or disable management ports:
1. From the Management Access menu, select Physical Ports Access.
The Physical Ports Access menu appears (see
2. From the Physical Ports Access menu, select None to disable both inband and
out-of-band management, MNG only to enable out-of-band management only
(via MNG port), or All to enable management via Ethernet management and
data ports.
Appendix B
illustrates connections between the management port, data port,
STM-1/OC-3c port and the CPU within internal bridge.
Whenever the Physical Ports Access mode is changed, the POS Port Egress
(STM-1/OC-3c) and Tag Stripping (data and management Ethernet ports) are set to
their default values as explained in
Appendix B
.
RIC-155
Physical Ports Access (All)
1. None
2. MNG only
3. All
Please select item <1 to 3>
ESC-prev.menu; !-main menu; &-exit
Figure 4-8. Physical Ports Access Menu
4.2
Configuring the RIC-155 for Operation
The RIC-155 management software allows you to perform the following:
• Setting source clock
• Defining control port parameters
• Defining alarm severity and masking alarms
• Resetting RIC-155 to the default values
• Performing the overall reset of the device.
Note