Configuring the network managers, Appears (see, Figure 4-4 – RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 User Manual
Page 40: Figure 4-5
Chapter 4 Configuration
RIC-155 Installation and Operation Manual
4-4
Configuring RIC-155 for Management
RIC-155
Host IP
1. Host IP List
>
2. Host default gateway (0.0.0.0)
3. Read community (public)
4. Write community (public)
5. Trap community (public)
6. Host Tagging (Tagged)
7. VLAN ID [1-4094] (1)
8. Host VLAN priority (1)
>
ESC-prev.menu; !-main menu; &-exit
Figure 4-4. Host IP Menu
RIC-155
Host IP List
1. IP Address (0.0.0.0)
2. IP Mask (0.0.0.0)>
ESC-prev.menu; !-main menu; &-exit
Figure 4-5. Host IP List Menu
Configuring the Network Managers
Define or modify the network management stations to which the SNMP agent of
RIC-155 sends traps. Up to ten managers can be defined. Entering the IP address
and corresponding subnet mask defines each management station. In addition,
you can temporarily prevent a manager station from receiving traps by masking
them.
To configure the network managers:
1. Follow the path: Configuration > System Configuration > Management >
Manager List
.
The Manager List menu appears (see
2. From the Manager List menu, select a management station by moving the
cursor up/down or left/right.
3. Enter a new IP address for the selected management station.
4. Move to the Trap Mask field and toggle between YES and NO to mask or
unmask traps for the selected management station.
5. Repeat step 2 and step 3 to define additional management stations.