Chapter 5. troubleshooting and diagnostics, Monitoring performance, Displaying the ethernet statistics – RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 User Manual
Page 61: Chapter 5 troubleshooting and diagnostics, 1 monitoring performance
Monitoring Performance
5-1
Chapter 5
Troubleshooting and
Diagnostics
This chapter describes the RIC-155 diagnostic functions, which include:
• Statistics collection
• Status indications
• Alarms.
5.1 Monitoring
Performance
RIC-155 has capabilities for collection of the Ethernet and SDH/SONET statistics.
Displaying the Ethernet Statistics
Performance statistic data is collected for the primary Ethernet port of RIC-155.
To display the Ethernet statistics:
1. From the Main menu, select Monitoring.
The Monitoring menu appears.
2. From the Monitoring menu, select Physical Ports Monitoring.
The Physical Ports Monitoring menu appears.
3. From the Physical Ports Monitoring menu, select Physical Port Statistics.
The Physical Port Statistics menu appears (see
Figure 5-1
).
4. From the Physical Port Statistics, select DATA Statistics to display the Ethernet
statistics collected for the primary Ethernet port.
The DATA Statistics screen appears (see
Figure 5-2
).
5. The DATA Statistics screen includes the following parameters:
RX OK frames – Number of valid frames received by the DATA port
TX OK frames – Number of valid frames transmitted by the DATA port
Run time – Time elapsed since the last RIC-155 power-up or statistics
clearing.
To clear Ethernet statistics:
• From the DATA Statistics, select Clear Statistics to clear all collected Ethernet
statistic data.
You can also clear all Ethernet and SDH/SONET statistic data by selecting Clear All
Statistics from the Physical Port Statistics menu.