Additional tasks, Changing the password, Table 4-2 – RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 User Manual

Page 54: 6 additional tasks

background image

Chapter 4 Configuration

RIC-155 Installation and Operation Manual

4-18 Additional

Tasks

Table 4-2. STM-1/OC-3c Port Status Parameters

Parameters Description Values

Uplink Connector

Type

Type of the

STM-1/OC-3c
interface connector

Two BNC – BNC coaxial connector
SC – Fiber optic SC connector
ST – Fiber optic ST connector
FC – Fiber optic FC connector
SF1 – SF1 fiber optic interface
SF2 – SF2 fiber optic interface
SF3 – SF3 fiber optic interface

Section SONET/SDH

section status

Normal – Normal
LOS – Loss of Signal is detected
LOF – Loss of Frame is detected

Line

SONET/SDH line

status

Normal – Normal
AIS – Alarm Indication Signal is detected
RDI – Remote Defect Indication is detected

Path SONET/SDH

path

status

Normal – Normal
AIS – Alarm Indication Signal is detected
RDI – Remote Defect Indication is detected
LOP – Loss of Pointer is detected
Trace Mismatch – Tx path trace mismatch is detected

Line Indication

Normal – Primary/management link operates properly
Major – A major alarm is detected on the uplink
Minor – A minor alarm is detected on the uplink

4.6 Additional

Tasks

Changing the Password

From the User Access menu change current passwords and display the list of users
and their access levels. Currently the following permanent user names are available
(case-sensitive): SU and USER with 1234 as default password.

To change the current password:
1. Follow the path: Configuration > System Configuration > Management >

Management Access > User Access.

The User Access menu is displayed (see

Figure 4-21

).

2. From the User Access menu, select the following:

Change Password

to assign a new password to the existing user name (SU

or USER). Password can contain up to eight characters.