Additional tasks, Changing the password, Table 4-2 – RAD Data comm 10/100BaseT to STM-1/OC-3 Converter RIC-155 User Manual
Page 54: 6 additional tasks
Chapter 4 Configuration
RIC-155 Installation and Operation Manual
4-18 Additional
Tasks
Table 4-2. STM-1/OC-3c Port Status Parameters
Parameters Description Values
Uplink Connector
Type
Type of the
STM-1/OC-3c
interface connector
• Two BNC – BNC coaxial connector
• SC – Fiber optic SC connector
• ST – Fiber optic ST connector
• FC – Fiber optic FC connector
• SF1 – SF1 fiber optic interface
• SF2 – SF2 fiber optic interface
• SF3 – SF3 fiber optic interface
Section SONET/SDH
section status
• Normal – Normal
• LOS – Loss of Signal is detected
• LOF – Loss of Frame is detected
Line
SONET/SDH line
status
• Normal – Normal
• AIS – Alarm Indication Signal is detected
• RDI – Remote Defect Indication is detected
Path SONET/SDH
path
status
• Normal – Normal
• AIS – Alarm Indication Signal is detected
• RDI – Remote Defect Indication is detected
• LOP – Loss of Pointer is detected
• Trace Mismatch – Tx path trace mismatch is detected
Line Indication
• Normal – Primary/management link operates properly
• Major – A major alarm is detected on the uplink
• Minor – A minor alarm is detected on the uplink
4.6 Additional
Tasks
Changing the Password
From the User Access menu change current passwords and display the list of users
and their access levels. Currently the following permanent user names are available
(case-sensitive): SU and USER with 1234 as default password.
To change the current password:
1. Follow the path: Configuration > System Configuration > Management >
Management Access > User Access.
The User Access menu is displayed (see
2. From the User Access menu, select the following:
Change Password
to assign a new password to the existing user name (SU
or USER). Password can contain up to eight characters.