Changing the lan ip address of a configured ir-ip, What to do if, Sectio – RAD Data comm E1 Interface Converter RIC-E1 User Manual
Page 67: Attempts, skip to the
RIC-E1 Installation and Operation Manual
Appendix D IR-IP Interface Module
Performing Preliminary Configuration
D-11
After changing the destination IP address of the Telnet host, it is recommended to
turn RIC-E1 off for a few seconds and then back on, before continuing the
configuration of the IP router in accordance with the
below. At this time, in Step 2 the ERR indicator turns off after the 15-second
interval.
Changing the LAN IP Address of a Configured IR-IP
The LAN IP address of an already-configured IR-IP can be changed while it
operates, this means it is not necessary to turn RIC-E1 off before starting the
configuration procedure. Note however that the IP traffic flow through IR-IP will
be disrupted until the other stations in the IP network learn the new address.
To change the LAN IP address of an already-configured IR-IP, use the procedure
described above for a new IR-IP with the following differences:
1. Configure the destination address of the ping utility to the new LAN interface
IP address. It is not necessary to change the Telnet host source address.
2. When ready, set section 1 of the IR-IP DIP switch to ON or push the IP LEARN
pushbutton on the RIC-E1/R panel.
The ERR indicator starts flashing faster (approximately four times a second).
3. Perform Steps 4, 5 of the procedure used for a new IR-IP.
What to Do If ...
After RIC-E1 is turned on, the INT (LINK for RIC-E1/R) indicator does not light
The IR-IP interface module does not receive power from the RIC-E1 power supply.
Service is required.
After RIC-E1 is turned on, the ERR indicator does not light
IR-IP is faulty and must be replaced.
After turn-on, the ERR indicator lights for 15 seconds and then turns off. ACT
does not light, and there is no response from IR-IP
No software loaded into IR-IP. Download software using the procedure described
in the
section below.
After turn-on, the ERR indicator lights for 15 seconds, and then turns off. ACT
lights from time to time, but there is no response from IR-IP
IR-IP has been configured. If you do not know the current IP address of the LAN
interface, erase IR-IP router configuration using the procedure given in the
No ping replies from IR-IP
If your host does not begin to receive ping replies after three unsuccessful
attempts, check the physical connection path between the Telnet host Ethernet
interface and the IR-IP 10BASE-T connector.
The IP learning process is not successful
Check that the prescribed IP address does not appear in the ARP table.
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com