beautypg.com

Operating ric-e1, Connecting the cables – RAD Data comm E1 Interface Converter RIC-E1 User Manual

Page 12

background image

Quick Start Guide

RIC-E1 Installation and Operation Manual

2 Operating

RIC-E1

Jumper Description Values

Default

Setting

JP2, JP3

Select the E1 interface type BALANCE – Balanced interface

(RJ-45 connector)

UNBALANCE

– Unbalanced

interface (BNC

coax connectors)

BALANCE

ALB DTE, JP4

Enables local analog

loopback activation from
the DTE (via pin 18 for

RS-530 or via pin “JJ” for

V.35)

EN

– The local analog loopback

activation from the DTE is
enabled

DIS

– The local analog loopback

activation from the DTE is
disabled



DIS

Note: The JP4 jumper is not available for RIC-E1/R cards with X.21 or Ethernet interfaces.

PNL SW, JP5

Enables activation of the
local analog loopback via

the front panel pushbutton

EN

– The LLB can be activated via

the front panel

DIS

– The LLB cannot be

activated via the front

panel

EN

Note: The JP5 jumper is not available for RIC-E1/R cards with IR-ETH and IR-ETH/V interface modules.

For RIC-E1/R with IR-IP interface module, the JP5 jumper serves for enabling or disabling the IP LEARN

pushbutton.

TX&RX CODE, JP6

Selects the data receive

and transmit coding

HDB3
AMI

HDB3

TIMING SEL, J2

Selects the clock reference

RCV

– Receive clock

EXT

– External clock

INT

– Internal clock

RCV

Note: Units with the IR-ETH, IR-ETH/V and IR-IP interface modules support only receive and internal clocks.

CHASS GND, J3

Controls the connection
between the RIC-E1/R

signal ground and the

frame (chassis) ground

CON

– Signal ground is

connected to the frame

ground

DISCON

– Signal ground is

disconnected from the
frame ground

CON

Connecting the Cables

To connect cables:
1. Connect the E1 line interface.
2. Connect the DTE interface.
3. Connect the power cable (first to the converter, then to the mains supply).

The PWR LED lights when power is connected.

2. Operating

RIC-E1

RIC-E1 operates entirely unattended except when performing system tests.

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com