Installing ric-e1/r into the asm-mn-214 card cage, Connecting the interfaces – RAD Data comm E1 Interface Converter RIC-E1 User Manual
Page 39
RIC-E1 Installation and Operation Manual
Chapter 5 RIC-E1/R Card
Installing the RIC-E1/R Card
5-7
Table 5-1. RIC-E1/R Jumper Settings (Cont.)
Jumper Description Values
Default
Setting
PNL SW, JP5
Enables activation of the
local analog loopback via
the front panel pushbutton
EN
– The LLB can be activated via
the front panel
DIS
– The LLB cannot be
activated via the front
panel
EN
Note: The JP5 jumper is not available for RIC-E1/R cards with IR-ETH and IR-ETH/V interface modules.
For RIC-E1/R with IR-IP interface module, the JP5 jumper serves for enabling or disabling the IP LEARN
pushbutton.
TX&RX CODE, JP6
Selects the data receive
and transmit coding
HDB3
AMI
HDB3
TIMING SEL, J2
Selects the clock reference
RCV
– Receive clock
EXT
– External clock
INT
– Internal clock
RCV
Note: Units with the IR-ETH, IR-ETH/V and IR-IP interface modules support only receive and internal clocks.
CHASS GND, J3
Controls the connection
between the RIC-E1/R
signal ground and the
frame (chassis) ground
CON
– Signal ground is
connected to the frame
ground
DISCON
– Signal ground is
disconnected from the
frame ground
CON
Installing RIC-E1/R into the ASM-MN-214 Card Cage
To install the RIC-E1/R card in the ASM-MN-214 card cage:
1. Install the ASM-MN-214 card cage in the 19-inch rack.
2. Insert the RIC-E1/R card into one of the ASM-MN-214 slots.
3. Push the card into the cage until it is fully inserted into the edge connector
inside the rack.
4. Tighten the screws on front panel of the modem card.
Connecting the Interfaces
RIC-E1/R uses the ASM-MN-214 rear panel terminal block ports for the line
connections. The 25-pin D-type female connector serves as a DTE port.
1. Remove the protection cover from the terminal block connectors.
2. Connect the terminal block to the ASM-MN-214 terminal block connector.
3. Connect the line to the terminal block as follows: connect transmit pair to the
terminals marked XMT, the receive pair to the terminals marked RCV, and the
fifth screw to ground (optional).