RIC-E1 Installation and Operation Manual
Chapter 1 Introduction
Technical Specifications
1-5
Diagnostics
Complies with ITU V.54 (loop 3)
Local Loopback
Activated by:
• Internal jumper (RIC-E1)
• Front panel pushbutton (RIC-E1/R)
• DTE circuit 141 for V.35, RS-530 and V.36
Power
AC Source
100 to 240 VAC (± 10%), 50 or 60 Hz
DC Source
• -48 VDC (-36 to -72 VDC)
• 24 VDC (18 to 36 VDC)
Power Consumption
• Standalone: 3W, max
• RIC-E1/R: 5.2W
Fuses
Standalone RIC-E1: 250 mA 250V slowblow
RIC-E1/R: 500 mA 250V slowblow
Physical
RIC-E1
Height
39.5 mm / 1.5 in
Width
190 mm / 7.4 in
Depth
160 mm / 6.2 in
Weight
0.6 kg / 1.3 lb
RIC-E1/R
Fits one slot in the ASM-MN-214 card cage
Environment
Temperature
0–50°C (32–122°F)
Humidity
Up to 90%, non-condensing
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com