Setting the dip switch, Led indicators, Figure b-5 – RAD Data comm E1 Interface Converter RIC-E1 User Manual
Page 49
RIC-E1 Installation and Operation Manual
Appendix B IR-ETH Interface Module
Installation and Operation
B-5
Figure B-5. IR-ETH DIP Switch and LED Locations
Setting the DIP Switch
describes functions and default settings of the DIP switch SW-1 sections.
The DIP switch is located on the reverse side of the IR-ETH module. To change the
switch settings, you must undo three screws on the board and detach the module
from the main unit.
Table B-2. DIP Switch Settings
Section Name
Description
Default Setting
1
SQ/FD
ON – Full-duplex operation
OFF – Half-duplex operation
OFF
2
CMP
ON – Strips padding bits inserted in 64-byte frame
OFF – Transmits frames over WAN as is
OFF
3
FIL
ON – Passes only frames destined for another LAN
OFF – Disables LAN filter; passes all frames transparently
OFF
4
– –
Permanently OFF
LED Indicators
and
list the IR-ETH LED indicators and describe their functions.
Table B-3. IR-ETH LED Indicators, Standalone RIC-E1
LED Name Description
Location
Color
LINK
ON – Good link integrity
Rear panel
Green
Note: The LINK indicator is not available for the IR-ETH module with BNC connector.
COLL
ON – Collision occurred on the attached Ethernet segment
Rear panel
Yellow
RX
ON – Data is received from the Ethernet attached segment
Rear panel
Yellow
TX
ON – Data is transmitted from RIC-E1 to the attached Ethernet
segment
Rear panel
Yellow
ERR D4
ON – Bridge buffer overrun
IR-ETH board Red