3. Usage (How to Use the Emulator Debugger)

REJ10J0777-0100 Rev.1.00 2005.08.01

Page 43 of 90

3. Usage (How to Use the Emulator Debugger)

This chapter describes how to start up the emulator debugger from the High-performance Embedded Workshop.

3.1 Starting Up the Emulator Debugger

When debugging the completed programs, switch the session. The session can be changed by the drop down list of the tool bar

shown below.

You will have as many sessions created as the number of targets you selected when creating a project, so select the session that

corresponds to the target to be connected from the drop-down list. To connect to the PC7501 + M16C Emulation Probe, select

“SessionM16C_R8C_PC7501_Emulator.”

3.1.1 INIT Dialog Box

After specifying the session, an Init dialog box to connect the target is displayed. The Init dialog box is used to set the items

that need to be set when the emulator debugger starts up. The contents set in this dialog box remain effective the next time you

start the debugger. When you have finished settings (1) through (4), click OK.

(1) MCU tab

1 Specifying the MCU file

Specifying the MCU file

Specifying the MCU file

(1) Click the “Refer…” Button”.

(2) ”Select MCU File” dialog box will be displayed.

Specify the MCU file “M16C6V_512.MCU” for the

target MCU.

- The MCU file contains the information specific to the

target MCU.

-

The MCU file you have selected is displayed in the
MCU section of the MCU tab.