83

Connection with the Uninterruptible Power System (UPS)

This is an example of connection with the uninterruptible power system (UPS) to be installed to protect from a power outage.
When a signal is supplied to the outage detection I/O terminals from the uninterruptible power system (UPS), internal process-
ing will be started to shut off the power supply for this unit.
After completing the internal processing, a signal will be supplied from the outage processing end output terminal to the unin-
terruptible power system (UPS). Then, the power supply to this unit can be suspended.

Connection of the control output

• When an alarm device such as a buzzer or a lamp is connected, the signal output from Pin Nos. 15 - 18 can be used to

notify the status by sounding a buzzer or lighting a lamp.

• The following example is of a connection with the HDD error output (pin no. 16).

!3

!6

Alarming device

Relay, etc.

(GND)

(HDD error output)

ALARM/CONTOROL

Install according
to your needs

Uninterruptible

power system

(UPS)

This unit

To an AC outlet

!3

@3

!9

(Outage processing end output)

(Outage detection I/O)

(GND)

Power cable

(Detection)

(Shutdown)

ALARM/CONTOROL

* Refer to the operating

instructions of the used
product for further
information about
connection of the UPS side.