Promise Technology FAST TRAK100TM User Manual
Page 78

FastTrak100 User Manual
74
10. After rebooting, use FastBuild to re-create the array. For mirrored arrays,
rebuild the mirrored array. For striped arrays, use FDISK and FORMAT after
setting up the array.
Array Constantly Goes Into Critical or Offline Mode During Reboot
(see “Unable to Partition or Format array” above)
Cannot Rebuild Mirrored (RAID 1) Array
(see “Unable to Partition or Format array” above)
Fatal Errors or Data Corruption Are Constantly Reported When Reading or
Writing to Drive Array
(see “Unable to Partition or Format array” above)
ECC Error Reported on Rebuild
The following screen will appear if a data error is detected on either source or target
drive during Rebuild if you have set the On Errors setting to “Interactive” within
FastCheck’s Options Window (see page 59).
Your choices are as follows:
Abort: Halts the rebuild process. You may elect to retry at a later date.
Break ECC on Target Drive: If the error is detected on the source drive,
“Break ECC on Target Drive” means that FastTrak will copy the bad
data sector on to the target drive to assure that both drives are identical.
If the error is detected on the target drive, FastCheck will copy the data
contained in the good sector of the source drive again to the target drive.
Skip the Error Block: FastTrak100 will log the event error and continue the
rebuild process. Use this setting if you want to detect the presence of