beautypg.com

Promise Technology FAST TRAK100TM User Manual

Page 51

background image

FastTrak100 User Manual

47

Status: (Functional, Critical, Offline)

Functional: Means the array is providing full functionality

Critical: Used only in reference to a Mirroring array (RAID 1 or RAID 0+1). A

problem has been detected in one of the drives of the array and the drive
has been taken “offline.” However, a “critical” array will continue to
save and retrieve data from the remaining working drive(s). Promise
recommends replacing the failed drive as soon as possible since a
“Critical” array offers no data redundancy.

Offline: This would appear most commonly within a RAID 0 or Spanning

array. The “Offline” results from a drive having failed which has taken
the entire array “offline.” In this case, you have likely lost data.
Fix/replace the drive that has failed, then restore data from a backup
source.

Viewing Arrayed Drive Information

By left-clicking on a drive member of an array in the left pane, the right pane shows
the following information categories for that drive:

Status (also shown under the Array Window) can be Functional, Critical, or

Offline. The meanings are shown below.

Functional: Means the drive is working normally

Critical: A problem has been detected in the drive and the drive taken offline

as part of a mirroring array. Mirrored arrays will continue to function
without the drive. Fix/replace the drive that has failed, then restore data
from a backup source.