beautypg.com

Determining the condition of the raid array – Powerware Model V-2000B User Manual

Page 94

background image

92 = Hard Disk Management

Determining the Condition of The RAID Array

Figure 32: Report of RAID Array Condition


To replace a failed drive in the RAID control utility, perform the following steps.

Select the [Remove Drive] option next to the DEGRADED drive.

The DEGRADED message next to the drive will change to NOT PRESENT.

If you suspect the drive is damaged, or if a previous Rebuild attempt has failed:
1. Power down the system.
2. Replace the failed drive with a drive of identical storage space. Detailed information

about how to replace hard drives is on page 110.

3. Restart the system.
4. Repeat the steps described earlier in this chapter – up to this point – then continue…

Click on the Rescan Controller button to identify available drives. The following window
will appear: