Maintenance, Fault diagnostics, Front panel indicators – Powerware Model V-2000B User Manual
Page 104
102 = Maintenance
Maintenance
Fault Diagnostics
Front Panel Indicators
The five LED indicators on the front panel are used to diagnose server fault conditions. The
meaning of each indicator is noted in the following table. During normal operation, all five
indicators will be on.
GENLOCK
OFF indicates that the Genlock setting
in the System menu is “Internal”
FLASHING indicates that Genlock is
selected in the System menu, but
there is no signal, or an invalid signal,
at the
GENLOCK input connector.
Check the Genlock setting in the On-
Screen System menu.
Check the Genlock cable connections
or signal.
POWER
FLASHING indicates that there is a
fault in the system power supply.
Shut down the Image Server and
contact 360 Systems Customer Support
for further hardware diagnosis.
FANS
FLASHING indicates that there is a
fault of the internal chassis fan.
Check the chassis fan operation.
Replace if necessary. Do not run the
Image Server without a working fan.
DRIVES
FLASHING indicates that there is a
fault in the system RAID array.
Check the RAID array status using
the utility under
START > RAID STATUS.
SYSTEM
FLASHING indicates that the CPU fan
is running slow, or stopped; or that the
CPU temperature or voltage is not
within manufacturer’s specification.
Shut down the Image Server and
contact 360 Systems Customer Support
for further hardware diagnosis.
Repairs should be performed only by qualified electronics
technicians.