88 = Hard Disk Management

P

10

11

12

RAID Level 5:

“Independent Access Array with Rotating Parity”
High Data Reliability & Transfer Capacity

Disk 2

Disk 1

Disk 0

Disk 3

4

5

P

6

1

2

3

P

7

P

9

8

Disk Array

Controller

DATA

Array Management Software

Provides Logical to Physical Mapping

Physical

Figure 29: RAID 5 Array Schematic

Improved Write Performance

The Image Server uses new designs to improve RAID-5 write performance for both large

sequential and small random transactions. This advanced block caching firmware delivers

extremely high performance for RAID-5 write operations.

Managing Disk Arrays

The Image Server’s Disk Array Configuration Utility provides tools for monitoring and

managing the disk array. Monitoring and troubleshooting programs automatically check the

array, report problems, and provide access to RAID status information and service options.
A single drive fault should not cause data loss, but the drive array is degraded and no longer

has storage redundancy. Hence, another disk failure may cause a complete loss of data and
system failure. After a drive failure it is strongly recommended that at the earliest time

diagnostics be performed, and the server be taken off line while the RAID array is rebuilt.

Error Notification and Repair

The Image Server will notify users in the event of a fault by flashing the front panel DRIVES

light. A flashing DRIVES light can be trigged by a variety of conditions. The first step in
response to a flashing light is to open the RAID CHECK STATUS window from the On-Screen

Start Menu. Click Start > RAID Status to launch the Array Configuration Utility.