beautypg.com

Recording, Setting up to record – Powerware Model V-2000B User Manual

Page 41

background image

Basic Operations = 39

Recording

Video recordings are made on the Image Server using the Channel 1 section of the graphic user

interface, or an external automation system. Channel 1 can also be used for playback when not

recording.

Setting up to Record

Image Servers were designed for use in genlocked facilities. Both the server and video sources

feeding it must be referenced to a common sync reference. This signal should conform to RS-

170 (composite video, black). When a genlocked source is not available, as in the case of

satellite receivers or non-professional tape machines, a frame synchronizer can be used to

create a synchronous source.

1

Alternatively, the video output of a stable source can be

connected to a distribution amplifier and applied both to the server genlock input and to its

video input.
Several steps must be taken before making a recording on the Image Server:
1. A genlock signal must be applied to the rear panel Genlock connector. The server will not

enter record mode if it does not detect the presence of a genlock signal. The genlock input

has a fixed 75-ohm termination. Do not add another termination at any point on the

genlock cable.

2. The external genlock signal must be selected as the sync reference, using the On-Screen

user interface.

A.

When working from the Serial Inputs, check the box marked SERIAL CONTROL.

B.

Eject any clip in Channel 1 and verify that the status window displays IDLE.

C.

From the main menu bar select CONFIGURE>SYSTEM.

D. Select GENLOCK as the sync source.

E.

Click APPLY followed by OK. The Configure window will close.

F.

Check that the front panel GENLOCK LED is now illuminated.

Note: The INTERNAL sync reference setting (a crystal) can be used for playback, but not
for recording.

3. A genlock signal must also be connected to equipment originating the video signal to be

recorded on the Image Server. (See introductory paragraph of this section if there is no

provision for a genlock signal.)

1

Video frame synchronizers are available from a number of manufacturers from about $800.