COMSPHERE 3800Plus Modems

8-20

October 1998

3980-A2-GB30-40

Table 8-3

(2 of 5)

Line Dialer Configuration Options

BusyTone Detect: Enable

Nxt

Enable

Disable

Busy Tone Detect. Sets the modem to monitor for Busy Tone (Enable) or ignore Busy Tone (Disable).

This configuration option is normally enabled; however, if the modem receives false busy tones, this configuration option
can be disabled and the modem ignores all busy tones.

The factory default is Enable.

AT command equivalent is X

n.

‘‘,” Pause Time: 2sec

Nxt

2sec

4sec

6sec

8sec

10sec

20sec

Pause Time. Determines the number of seconds the modem pauses when it encounters a comma (,) in the dial
command string.

NOTE: Although DCP selections are limited (2, 4, 6, 8, 10, or 20), values set by the AT commands can display from 0 to

255 seconds.

The factory default is 2sec.

AT command equivalent is S-register S8=

n.

NoAnswer Timout: 45sec

Nxt

45sec

30sec

60sec

120sec

No Answer Abort Time-out. Determines the number of seconds an originating modem waits before abandoning a call
attempt when no answer tone is received.

NOTE: Although DCP selections are limited (30, 45, 60, or 120), values set by AT commands can display from 1 to

255 seconds.

The factory default is 45sec.

AT command equivalent is S-register S7=

n.

Fast Disconnect: Disable

Nxt

Disable

Enable

Fast Disconnect. Allows the modem to disconnect immediately after receiving a disconnect command from a local DTE
or its own diagnostic control panel.

Disable – The modem follows its normal disconnect sequence by issuing a cleardown sequence or long space
disconnect. This is also known as a graceful disconnect since the other modem receives advance notice of a
disconnection.

Enable – Use this setting if the DTE requires that the modem be made available as soon as possible after receiving a
disconnect command.

NOTE: This abrupt method of disconnecting may cause problems with the remote modem, which may interpret the

disconnection as an error instead of a valid disconnect.

The factory default is Disable.

AT command equivalent is S-register S85=