beautypg.com

Paradyne 3800PLUS User Manual

Page 161

background image

AT Command Set and S-Registers

13-27

3980-A2-GB30-40

October 1998

Table 13-2

(10 of 15)

3800

Plus S-Registers

AT Command

Front Panel Branch

Description

S53

V.54 Address
Identifies the address of the modem to be placed in a loopback test.

Register has the following values:

0 =Disable

1–34 =Modem address

Factory setting is Disable.

Configure\Edit\Tests

S54

V.54 Device Type
Identifies where the modem is physically located in the network.

Register has the following values:

0=Peripheral
1=Intermediate

Factory setting is Peripheral.

Configure\Edit\Tests

S55

Access from Remote
Register determines if a modem’s DCP can be accessed by a remote
modem.

Register has the following values:

0=Enable
1=Disable

The factory default templates do not affect S55.

Configure\Edit\Misc

S56

Remote Access Password (Part 1)
Register allows entry of the first pair (leftmost) of digits of a remote access
password. Any value from 00 to 99 is valid. For example, if the remote
access password is 12345678, then S56=12.

Configure\Edit\Misc

S57

Remote Access Password (Part 2)
Register allows entry of the second pair of digits of a remote access
password. Any value from 00 to 99 is valid.

Configure\Edit\Misc

S58

Remote Access Password (Part 3)
Register allows entry of the third pair of digits of a remote access
password. Any value from 00 to 99 is valid.

Configure\Edit\Misc

S59

Remote Access Password (Part 4)
Register allows entry of the fourth pair (rightmost) of digits of a remote
access password. Any value from 00 to 99 is valid.

Configure\Edit\Misc

S61

CT111 Rate Control
Register determines if CT111 Rate is disabled, set for Fallback 1 or
Fallback 2. CT111 Rate allows the DTE to control modem rate via Pin 23
of the EIA-232-D interface. This configuration option determines the effect
of the DTE Rate Control signal. It is only valid in Async Direct mode and
Synchronous mode. For proper operation, disable the V32bis Autorate and
V32bis Automode configuration options.

Register has the following values:

0=Disable
1=Fallback 1
2=Fallback 2

Factory setting is Disable.

Configure\Edit\
DTE Interface