beautypg.com

Paradyne 3800PLUS User Manual

Page 166

background image

COMSPHERE 3800Plus Modems

13-32

October 1998

3980-A2-GB30-40

Table 13-2

(15 of 15)

3800

Plus S-Registers

AT Command

Front Panel Branch

Description

S92

V.29 Train On Data
Register determines whether the modem must receive a standard V.29
training sequence in order to enter data mode (Disable) or whether it
should use the received data mode for training (Enable). Effective only if
the V.29 feature is installed and V.29 is selected for the leased-line rate.

Register has the following values:

0=Disable
1=Enable

Factory setting is Disable.

Configure\Edit
Leased Line

S93

RJ11 Cellular Adapt
Valid only if ETC is installed, register controls support for an RJ11
connection, including generation of the ETC 1.1 Calling Tone during call
origination.

Register has the following values:

0=Disable
1=Enable

Factory setting is Disable.

Configure\Edit\Misc