AT Command Set and S-Registers
13-13
3980-A2-GB30-40
October 1998
Table 13-1
(11 of 15)
3800
Plus AT Commands
AT Command
Front Panel Branch
Description
\A
n
Error Control Maximum Frame Size
\A0
64
\A1
128
\A2
192
\A3
256
\A4
32
\A5
16
Configure\Edit\
V42/MNP/Buffer
\C
n
Error Control Negotiate Buffer
\C0
Disable.
\C1 Enable.
\C2
Disables and switches modem to Buffer mode.
Configure\Edit\
V42/MNP/Buffer
\D
n
CTS Control
\D0
Forced On. Forces CTS to always ON.
\D1 Standard
RS232.
\D2
Wink When Disconnect. CTS is turned Off for 1 to 2 seconds upon
a disconnect.
\D3
Follows DTR. The state of CTS follows the state of DTR.
Configure\Edit\
DTE Interface
\G
n
Modem to Modem Flow Control
\G0
Disable.
\G1 Enable.
Configure\Edit\
V42/MNP/Buffer
\K
n
Break Buffer Control, Send Break Control, Break Forces Escape
Break
Send
Break
Buffer
Break
Forces
Control
Control
Escape
\K0
Discard Data
Break First
Enable
\K1
Discard Data
Break First
Disable
\K2
Keep Data
Break First
Enable
\K3
Keep Data
Break First
Disable
\K4
Keep Data
Data First
Enable
\K5
Keep Data
Data First
Disable
\K6
Discard Break
Not Applic.
Disable
Break Buffer Control:
Configure\Edit\
V42/MNP/Buffer
Send Break Control:
Configure\Edit\
V42/MNP/Buffer
Break Forces Escape:
Configure\Edit\
DTE Dialer
\N
n
Error Control Mode
\N0
Buffer Mode.
\N1 Direct
Mode.
\N2
MNP or Disconnect.
\N3
MNP or Buffer.
\N4
V.42/MNP or Disconnect.
\N5
V.42/MNP or Buffer.
\N6
LAPM or Disconnect.
\N7
LAPM or Buffer.
Configure\Edit\
V42/MNP/Buffer