Rem Digital Loop

Rem Digital Loop performs a remote digital loopback

(ITU-T V.54 Loop 2), Figure 7-2. This test can verify the
integrity of the local modem, the communications link,
and the remote modem. Any data or pattern entered at the
local DTE is sent to and returned from the remote modem.
For this test to operate properly, the modems must be
online and in Synchronous or Asynchronous Direct mode
and, if set for V.34 modulation, must not be in
Asymmetric Rate mode.

To access Rem Digital Loop from the Test branch,

make the following selections:

F1

Test :
Rem_Digital_Loop

F2

F3

Press the

key until Rem Digital Loop appears.

Press any function key to start this test.

F1

Test : Remote Loop
Started

F2

F3

The message Started appears on the LCD, and the Test

LED lights for the duration of the test.

If the Test Timeout configuration option is enabled,

Test Timeout appears at the conclusion of the test. If it is
disabled, the test operates until aborted. For more
information on the Test Timeout configuration option,
refer to the

Test

section in Chapter 8, Configure Branch.

To exit this function and remain in the Test branch,

press the

key. To exit and return to the Top-Level

menu, press the

key.

AT Command Equivalent

The AT command for Remote Loopback is &T6.