beautypg.com

Paradyne 3800PLUS User Manual

Page 150

background image

COMSPHERE 3800Plus Modems

13-16

October 1998

3980-A2-GB30-40

Table 13-1

(14 of 15)

3800

Plus AT Commands

AT Command

Front Panel Branch

Description

%R

Async DTE Rate
Sets the DTE rate for Asynchronous mode. This configuration option has
no effect in Sync or Async Direct modes, where the DTE rate always
equals the VF rate.

%R

n must be the last command in a command string.

The %R

n command does not disable autobauding. If a command is

received from the DTE at a new rate, the modem will autobaud to that rate,
replacing the current %R value. If a factory preset is selected with an
AT&F

n command, the autobauding rate is not changed.

Rates above 19,200 bps are not defined in RS232E, but can function
correctly in many cases. For higher rates, take the following precautions:

Use as short a DTE cable as possible. A special low-capacitance cable

may be required.

For an IBM-compatible PC, ensure that the serial port uses a buffered

UART such as the 16550.

If you experience overruns, it may be that your DTE cannot handle higher
DTE rates. Try a lower value.

%R300

0–300 bps

%R1200

1200 bps

%R2400

2400 bps

%R4800

4800 bps

%R7200

7200 bps

%R9600

9600 bps

%R12000

12,000 bps

%R14400

14,400 bps

%R19200

19,200 bps

%R28800

28,800 bps

%R38400

38,400 bps

%R57600

57,600 bps

%R76800

76,800 bps

%R115200

115,200 bps

Configure\Edit\
DTE Interface

#DM

n

SDC Delay Minimization
Minimizes the delay introduced by SDC by allowing the modem to
transmit a DTE frame to its DTE in a discontinuous way.

#DM0

No delay minimization. The modem does not begin
transmitting a frame to its DTE until the entire frame has been
received.

#DM1

Delay minimization. The modem begins to transmit data from
a DTE frame to its DTE even if the end of the DTE frame has
not yet been received by the modem.

Configure\Edit\
V42/MNP/Buffer

#Q

n

Sync Flow Ctrl
Controls the type of synchronous data flow control while using data
compression.

#Q0

No flow control.

#Q1

Flow control using transmit clock (circuit 114).

#Q2

Flow control using CTS (circuit 106).

Configure\Edit\
V42/MNP/Buffer