Troubleshooting, Modem integrity, Appendix c – Paradyne 3800PLUS User Manual
Page 175: Provides instructions for performing, If the modem does not return, Overview
C-1
3980-A2-GB30-40
October 1998
Troubleshooting
Overview
that can occur when operating a 3800Plus modem. Use
Tables C-1 through C-6 to check out these problems. If
you are having data communication difficulties, such as
periodic character loss, random errors, or constant format
errors, use the loopback tests described in Chapter 7,
. With these tests you can usually isolate the fault
in your system by using the process of elimination. If
problems continue to occur, contact your service
representative.
Table C-1
Modem Integrity
Symptom
Action
Modem did not pass power-up self-test
Contact your service representative.
Power LED does not light
LCD does not display
Make sure the modem’s ON/Off switch is in the ON position.
Make sure the ac power transformer is connected to the ac power receptacle.
If Power LED and/or LCD do not operate, contact your service representative.
A problem is suspected after the
power-up self-test
Perform a self-test via the modem’s DCP or type AT&T9 if using AT
commands.
Perform a local analog loopback with a Pattern test. If the modem consistently
registers errors, contact your service representative.
If the modem passes the above tests and a problem still exists, then the
problem is likely not with your modem.