Paradyne 3800PLUS User Manual

Page 163

background image

AT Command Set and S-Registers

13-29

3980-A2-GB30-40

October 1998

Table 13-2

(12 of 15)

3800

Plus S-Registers

AT Command

Front Panel Branch

Description

S74

Network Position Identification
Register identifies each modem as either a control or tributary modem.

Register has the following values:

0=Tributary
1=Control

Factory setting is Tributary for the 3810

Plus.

Factory setting is Control for the 3811

Plus.

Configure\Edit\Misc

S75

Network Management Address
Register determines the modem’s network address. This address is used
when accessing the modem from the NMS.

Enter a value from 0 (network address 001) to 255 (network address 256).

The factory default templates do not affect S75.

Configure\Edit\Dial

S76

Autorate (Dial Line)
Register determines if Autorating is used on dial lines when connected in
V.32bis or V.34 mode.

Register has the following values:

0=Enable
1=Disable
2=Start at 4800 bps
3=Start at 9600 bps

Factory setting is Enable.

Configure\Edit\
Dial Line

S77

DTR Alarm Reporting
Register determines whether an alarm is sent to the NMS controller when
the DTR signal has been off for more than 10 seconds.

Register has the following values:

0=Disable
1=Enable

The factory default templates do not affect S77.

Configure\Edit\Misc

S78

Automode (Dial Line)
Register allows the modem (when operating on dial lines) to automatically
detect and connect to the remote modem’s modulation scheme.

If the modem is in a modem pool attached to a System 85 Private Branch
Exchange (PBX), S78 should be set to 2. This modifies parameters used
during connection to the PBX.

Register has the following values:

0=Enable
1=Disable
2=System 85

Factory setting is Enable.

Configure\Edit\
Dial Line