Technical Specifications for COMSPHERE 3800

Plus Modems

Specifications

Criteria

COMPATIBILITY

DIAL-LINE MODULATIONS

ITU-T V.34 (33,600, 31,200, 28,800, 26,400, 24,000, 21,600, 19,200,
16,800, 14,400,12,000, 9600, 7200, 4800, 2400 bps)
Proprietary V.32

terbo (19,200, 16,800 bps)

ITU-T V.32bis (14,400, 12,000, 9600, 7200, 4800 bps)
ITU-T V.32 (9600, 4800 bps)
ITU-T V.22bis (2400 bps)
ITU-T V.22 (1200 bps)
ITU-T V.21 (300 bps)
Bell 212A (1200 bps)
Bell 103J (300 bps)

LEASED-LINE MODULATIONS

ITU-T V.34 (33,600, 31,200, 28,800, 26,400, 24,000, 21,600, 19,200,
16,800, 14,400, 12,000, 9600, 7200, 4800, 2400 bps)
Proprietary V.32

terbo (19,200, 16,800 bps)

ITU-T V.32bis (14,400, 12,000, 9600, 7200, 4800 bps)
ITU-T V.32 (9600, 4800 bps)
ITU-T V.33 (14,400, 12,000 bps) (optional)
ITU-T V.29 (9600, 7200, 4800 bps) (optional)
ITU-T V.22bis (2400 bps)

FAX MODULATIONS

ITU-T V.17 (14,400 bps)
ITU-T V.29 (9600, 7200 bps)
ITU-T V.27ter (4800, 2400 bps)

DATA RATES

Dial Line

33,600, 31,200, 28,800, 26,400, 24,000, 21,600, 19,200,16,800,
14,400, 12,000, 9600, 7200, 4800, 2400, 1200, or 300–0 bps

Leased Line

33,600, 31,200, 28,800, 26,400, 24,000, 21,600, 19,200,16,800,
14,400, 12,000, 9600, 7200, 4800, or 2400 bps

DTE RATES

115,200, 76,800, 57,600, 38,400, 28,800, 14,400, 12,000, 9600, 7200,
4800, 2400, 1200, 0–300 bps

ERROR CONTROL

ITU-T V.42
MNP 4–2

DATA COMPRESSION

ITU-T V.42bis
MNP Class 5
Proprietary Synchronous Data Compression (optional)

ENVIRONMENT

Operating Temperature

32

°

F (0

°

C) to 122

°

F (50

°

C)

Relative Humidity

5% to 90% (noncondensing)

Shock and Vibration

Withstands normal shipping

Storage Temperature

– 4

°

F (–20

°

C) to 158

°

F (70

°

C)