beautypg.com

Paradyne 3800PLUS User Manual

Page 86

background image

COMSPHERE 3800Plus Modems

8-26

October 1998

3980-A2-GB30-40

Table 8-4

(3 of 4)

Dial Line Configuration Options

Dial TX Level: Permissv(– 9)

Nxt

Permissv(– 9) –10 dBm –11 dBm –12 dBm –13 dBm –14 dBm –15 dBm –16 dBm –17 dBm

–18 dBm –19 dBm –20 dBm –21 dBm –22 dBm –23 dBm –24 dBm –25 dBm –26 dBm –27 dBm
–28 dBm –29 dBm –30 dBm –31 dBm –32 dBm ETC 1.0_Cell ETC 1.1_Cell

Dial Transmit Level. Sets the power output level of the transmit signal over dial lines.

Permissive (– 9 dBm) – The modem transmits data at approximately – 9 dBm. This is true whether the modem is
connected to an RJ11-type permissive jack or to an RJ41 or RJ45 programmable jack.

ETC 1.0_Cell – Displayed only if Enhanced Throughput Cellular (ETC) is installed. Transmit level is automatically
adjusted in response to line conditions according to the proprietary ETC 1.0 specification

.

Use only with remote modems

set to ETC 1.0_Cell, and limit the data rate to 4800 bps.

ETC 1.1_Cell – Displayed only if ETC is installed. Transmit level is automatically adjusted in response to line conditions
according to the proprietary ETC 1.1 specification

.

The factory default is Permissv(– 9).

AT command equivalent s are &

I

n and &Jn.

V22b Guard Tone: Disable

Nxt

Disable

550Hz

1800Hz

V.22bis Guard Tone. Determines whether the V.22bis guard tone is disabled, set to 550 Hz, or set to 1800 Hz.

Disable – No guard tone.

550 Hz or 1800 Hz – When the modem is in Answer mode, it transmits the guard tone at this frequency.

The factory default is Disable.

AT command equivalent is &G

n.

Train Time: Long

Nxt

Long

Short

Train Time. Controls V.34, V.32

terbo, V.32bis, and V.32 train. Determines whether minimum or maximum time durations

are used during the handshaking sequence for both dial and leased line applications.

NOTE: This configuration option only appears when the Dial Line Rate configuration option is set for V.34, V.32

terbo,

V.32bis, or V.32.

Long – Selects long train. Use this setting whenever far-end frequency offset (phase roll) may be encountered. This is
usually only required when transmitting over satellite links.

Short – Allows the modem to train-up faster.

The factory default is Long.

AT command equivalent is S-register S43=

n.

Asymmetric Rate: Enable

Nxt Enable Disable

Asymmetric Rate. Controls rate symmetry when running V.34 modulation. (This configuration option does not appear
unless V.34 modulation is selected.)

Enable – The modem operates in asymmetric rate mode (the transmit and receive rates can be different) when running
V.34 modulation. Asymmetric Rate must be enabled in both modems.

Disable – The modem operates in symmetric rate mode (the transmit and receive rates are identical) when running
V.34 modulation. Either modem can force symmetric mode by disabling Asymmetric Rate.

The factory default is Enable.

AT command equivalent is S-register S14=