IOLAN DS1/TS2 User’s Guide, Version 3.4

195

Setting Jumpers

Appendix C

C

Introduction

The IOLAN contains jumpers that you might need to set before you configure it and put it into
production. You can set the IOLAN line termination to

on

or

off

(this is

off

by default) if you are

using EIA-422/485 (not applicable for I/O models).

1-Port IOLAN

IOLAN DB25 Male/Female

To change the settings, do the following:

1.

Unplug the IOLAN from the electrical outlet and disconnect everything from the box.

2.

Open the case by unscrewing the two side screws, one on each side, and lifting off the top of the
case. You should see the following:

3.

To turn line termination

on

, locate and jumper both J1 and J9.

4.

Close the IOLAN case by replacing the case lid and the two screws. You can now power it on
with the new settings.

Power

Dip

Switch

Reset

RJ45

Ser

ia

l Con

nection

Screw

Screw

J1

J9