Perle Systems Perle IOLAN DS1 User Manual
Page 145

145
Channels
Active Signal
Width
How long the channel will be active during the pulse mode.
Range: 1-9999 x 100 ms
Default: 1 (100 ms)
Delay
How long to delay an active-to-inactive or inactive-to-active setting after it is
manually started.
Range: 1-9999 x 100 ms
Default: 1 (100 ms)
Failsafe Action
When there has been no I/O activity within the specified time (set in the I/O
Interfaces, Settings on the Failsafe Timer tab) and the
Failsafe Timer
is
triggered.
Data Options:
z
None—The state of the Digital/Relay output remains the same, no change.
z
Activate Output—Activates the channel.
z
Deactivate Output—Deactivates the channel.
Default: None