Major operating controls and their functions, Front view – Panasonic WJ-NT204 User Manual
Page 11
![background image](/manuals/169503/11/background.png)
11
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
■
Front View
LINK/
10BASE-T
100
BASE-TX CONNECT
ACT
LOW
HIGH
RING.VOL
Network Interface Unit WJ-NT
POWER
ON
OFF
RS-232C
RESET
HOST PORT
MODE
q
w e r t y
u
i
o
!0
q
Power Switch & Power Indicator [POWER]
Press this switch to turn on or off the power of the unit.
The indicator lights while the power is turned on.
w
[LINK/10BASE-T] indicator
Lights when communication is established through
lines (LINK) or a 10BASE-T LAN.
e
[100BASE-TX] indicator
Lights when communication is established through a
100BASE-T LAN, along with the LINK/10BASE-T indica-
tor.
r
[CONNECT] indicator
Lights when signaling the data only in H.261 mode.
t
[ACT] indicator
Blinks when receiving and sending IP packets.
y
Ringer Volume Control [RING. VOL]
Turn this control to adjust the sound level that beeps
when receiving a call.
u
Ringer Buzzer
Beeps when receiving a call only in H.261 mode.
i
Reset Button [RESET]
Pressing this button shuts down the current operation
and restarts the system.
o
RS-232C Host Port [RS-232C HOST PORT]
The unit communicates with the host computer through
this D-Sub 9-pin connector. Setting the MODE DIP
switch #9 specifies the mode and usable port from
among RS-485 (Rear Panel) and RS-232C (Front
Panel). Available controls are as follows.
• Communication control such as calling and discon-
nection
• Up/Download for software
• Download for communication log and alarm log
RS-232C
HOST PORT
q
y u i o
w e r t
RS-232C Host Port
No.
Signal
Function
Direction as seen from
name
WJ-NT204
1
C D
Receiver carrier
Input
detection
2
R D
Receiving data
Input
3
S D
Sensing data
Output
4
E R
Data connection ready
Output
5
S G
Signal Ground
–
6
D R
Data set ready
Input
7
R S
Request send
Output
8
C S
Send enabled
Input
9
N. C.
(Not used)