beautypg.com

Troubleshooting & repair, Caution – Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B User Manual

Page 79

background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-19

F-19

POWER WAVE 450

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

WELDING PROBLEMS

Machine loses output while weld-
ing. Fans and display are func-
tioning properly.

1. Check the yellow High

Temperature light on the front-
panel. If the light is “ON,” then
refer to the Output Problems
section in this table relating to
this condition.

2. Check for proper input volt-

ages (per machine nameplate).

3. Check for balanced three-

phase input supply voltages.

4. Check electrode and work

cables for loose or poor con-
nections.

1. Perform the Welding

Feedback Test.

2. Perform the Switch Board

Test.

3. Perform the Snubber and

Bleeder Resistor Test.

4. Perform the Static Capacitor

Balance Test.

5. Perform the Dynamic

Capacitor Test.

6. Perform the appropriate Wire

Feeder Trigger Circuit Test.
If a K941-1 Remote Control Kit
is used, perform the K941-1
Remote Control Kit Trigger
Circuit Test.