TROUBLESHOOTING & REPAIR
F-19
F-19
POWER WAVE 450
TROUBLESHOOTING GUIDE
Observe Safety Guidelines
detailed in the beginning of this manual.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
WELDING PROBLEMS
Machine loses output while weld-
ing. Fans and display are func-
tioning properly.
1. Check the yellow High
Temperature light on the front-
panel. If the light is “ON,” then
refer to the Output Problems
section in this table relating to
this condition.
2. Check for proper input volt-
ages (per machine nameplate).
3. Check for balanced three-
phase input supply voltages.
4. Check electrode and work
cables for loose or poor con-
nections.
4. Perform the Static Capacitor
6. Perform the appropriate Wire
Feeder Trigger Circuit Test.
If a K941-1 Remote Control Kit
is used, perform the K941-1
Remote Control Kit Trigger
Circuit Test.