Illustrated by figure b.10, By figure b.11, Power wave – Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B User Manual

Page 31: Positive voltage sensing polarity, Negative voltage sensing polarity, Operation

background image

Use the ELECTRODE SENSE LEAD KEY to select
either the - output terminal or the electrode sense (67)
lead for the positive voltage reference.

The work sense (21) lead is used only in rare circum-
stances. For most installations, use the WORK
SENSE LEAD KEY
to select the - output terminal for
negative voltage reference. Consult the factory if use
of the work sense (21) lead is desired.

The two wire feeders can only be connected in the
same manner, either by the Positive Polarity or the
Negative Polarity setup.

OPERATION

B-19

B-19

POWER WAVE 450

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

+

-

Power

Wave

Control Cable (includes 67 lead)

67

Electrode Sense Lead

Electrode Cable

Work Cable

Wire Feeder

Block

POSITIVE VOLTAGE SENSING POLARITY

FIGURE 11B

+

-

Power

Wave

67

Electrode

Cable

Work Cable

Wire Feeder

Block

NEGATIVE VOLTAGE SENSING POLARITY

FIGURE 11C

Control Cable (includes 67 lead)

Electrode Sense Lead

FIGURE B.10

FIGURE B.11