beautypg.com

Est (g3165-1) see table f.6, Table f.6, Troubleshooting & repair – Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B User Manual

Page 133

background image

F-73

F-73

IGBT/SWITCH BOARD TEST (G3165-1)

TABLE F.6 – NOTE: This test will NOT determine if an individual IGBT device is open.

TROUBLESHOOTING & REPAIR

POWER WAVE 450

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Apply

Apply

Positive

Negative

Test

Test

Probe to

Probe to

Test

Repair

Next

Terminal

Terminal

Result

Conclusion

Action

Procedure

2/4

12

Greater than OK

None

Continue

1k ohms

Less Shorted

Replace

Snubber

than 1K

Switch

Resistor

ohms

Boards

Test

9

1/3

Greater

OK

None

Continue

than 1K
ohms

Less than

Shorted

Replace

Snubber

1k ohms

Switch

Resistor

Boards

Test

2/4

9

Less

OK

None

Continue

than 100
ohms

Greater than Open

Replace

Snubber

1k ohms

Switch

Resistor

Boards

Test

9

2/4

Greater than OK

None

Continue

1k ohms

Less

Shorted

Replace Snubber

than 1K

Switch

Resistor

ohms

Boards

Test

NOTE: K ohm = ohm reading multiplied by 1000.